Industrial Transformers
K-Rated Transformers
Magnetic Control & Electricals K-Factor Transformers address the problems caused by non-linear loads and harmonics. They also compensate for stresses on a transformer’s winding insulation which prevents insulation…
-
High EfficiencyLower energy losses
-
Reliable PerformanceLong service life
-
IEC CertifiedMeets global standards
Price on Request
-
Free ShippingOn orders over £500
-
Secure Payment100% secure checkout
-
2 Year WarrantyManufacturer warranty
Product Overview
Magnetic Control & Electricals K-Factor Transformers address the problems caused by non-linear loads and harmonics. They also compensate for stresses on a transformer’s winding insulation which prevents insulation breakdown and premature failure. The net result is longer transformer life.
- Neutral to withstand 200% current
- High harmonic current carrying capacity with low eddy current loss
- High grade core material and 99.99% electrolyte conductor material
- Transformer can be designed with both copper and aluminium wound
- High & Low Voltage Overload Alarms
- Over Temperature Alarms
| K-Rating | K-1, K-4, K-7, K-13, K-20 |
|---|---|
| Standards | ANSI/IEEE C57.12.01 |
| Winding Material | Copper or Aluminium |
| Neutral Rating | 200% current |
| Impedance | As per IS 2026 standards |
| Enclosures | As per IP or NEMA Standards |
| Operating Temperature | Ambient 0°C to 55°C |
| Storage Temperature | Ambient 0°C to 55°C |
| Frequency | 60 Hz (57 – 63 Hz), 50 Hz on request |
| Relative Operating Humidity | 90% Non Condensing |
What is K-factor?
- K-factor is a value how much transformer can withstand harmonics without increase in maximum temperature value. A standard transformer cannot handle harmonics due to non linear loads. When harmonics enter into the transformer the core gets saturated as a result it produces lots of heat and failure of transformers.
- K-rating differs according to harmonic levels like K-1, K-4, K-7, K-13, K-20.
Features of Magnetic Controls K-Rated Transformer
- Magnetic and Controls manufactures transformers based on the current spectrum considering the de-rating factor and oversizing factor.
- Magnetic and Controls manufactures K-rated transformer in compliance with ANSI/IEEE C57.12.01
- Transformer can be designed with both copper and aluminium wound
- Neutral to withstand 200% current
- High grade core material and 99.99% electrolyte conductor material
- High harmonic current carrying capacity with low eddy current loss
- Impedance with compliance to IS 2026 standards and noise attenuation
Salient Features of Magnetic Controls K-Rated Transformer
- High thermal withstanding capacity
- Low losses
- High Efficiency
- High & Low Voltage Overload Alarms
- Over Temperature Alarms
- Customer Friendly Design
- Rugged Construction
- Enclosures are as per IP or NEMA Standards
- Mitred Core Joints to K Rated Standards
- Operating Temperature: Ambient 0°C to 55°C
- Storage Temperature: Ambient 0°C to 55°C
- 60 Hz Operating Range: 57 – 63 Hz and also 50 Hz as per customer request
- Relative Operating Humidity : 90% Non Condensing
Technical Specifications
- K-Rating
- K-1, K-4, K-7, K-13, K-20
- Standards
- ANSI/IEEE C57.12.01
- Winding Material
- Copper or Aluminium
- Neutral Rating
- 200% current
- Impedance
- As per IS 2026 standards
- Enclosures
- As per IP or NEMA Standards
- Operating Temperature
- Ambient 0°C to 55°C
- Storage Temperature
- Ambient 0°C to 55°C
- Frequency
- 60 Hz (57 – 63 Hz), 50 Hz on request
- Relative Operating Humidity
- 90% Non Condensing